Leave Your Message

High Capacity Liquid Asphalt Storage Tank System - China Suppliers & Factory for Asphalt Mixing Solutions

Introducing our high-performance liquid asphalt storage tank, expertly designed for the safe and efficient storage of high-temperature liquid asphalt. Made from durable, sealed steel, this tank features advanced thermal insulation and heating systems to prevent solidification and extend the lifespan of the asphalt. Our product is ideal for use alongside solid asphalt melters, allowing seamless transfer of liquid asphalt directly into the storage tank. This ensures steady temperature control, enabling continuous discharge for asphalt mixing plants and road construction projects. As a leading supplier in China, our factory is committed to delivering top-quality solutions tailored to meet the needs of the asphalt industry

    Product Description

    A liquid asphalt storage tank is a sealed steel tank used for long-term, large-capacity storage of high-temperature liquid asphalt. It is the core equipment for material storage, thermal insulation, and transfer in asphalt mixing plants, modified asphalt production lines, waterproofing membrane manufacturing, and the carbon industry, providing a stable source of asphalt for the entire production system.

    Main Classification

    By Structure

    • Horizontal asphalt storage tank: Most commonly used, standard for job sites/asphalt mixing plants. Capacity 5–100 tons, movable, fast installation, small footprint.
    • Vertical asphalt storage tank: Large fixed storage tank, capacity 100–5,000 tons, used for asphalt depots and large mixing plants, high storage capacity.

    By Heating Method

    • Thermal oil circulation heating: Most recommended. Uniform heating, no asphalt coking or aging, stable temperature control. Industry mainstream.
    • Fuel oil/gas direct heating: Fast temperature rise, low cost, suitable for remote job sites.
    • Electric heating: Clean with no open flame, suitable for waterproofing and small repair projects.

    Core Structure

    • Inner tank: Q235B carbon steel (6–10 mm), resistant to high-temperature corrosion. Equipped with localized rapid heating zone and ultra-low extraction port.
    • Insulation layer: 100–150 mm high-density rock wool/aluminum silicate with aluminum cladding. Temperature drop <1°C/h.
    • Outer shell: Carbon steel protective cladding, weatherproof against rain and sun.
    • Auxiliary systems: Automatic temperature control (130–160°C), asphalt pump, level gauge, pressure gauge, and breather valve.

    Key Technical Features

    Localized Rapid Extraction
    Only heats the discharge zone instead of the entire tank, saving energy and preserving asphalt quality.

    Constant Temperature
    Maintains fluid state throughout storage, preventing solidification, carbonization, and degradation.

    Environmental Protection
    Equipped with breather valve and fume collection system to reduce emissions.

    Common Specifications

    Small Job Sites 5t, 10t, 20t Horizontal Tanks
    Medium Mixing Plants 30t, 50t, 80t, 100t Horizontal Tanks
    Large Asphalt Depots 200t – 2000t Vertical Tanks

    Operating Principle

    Hot liquid asphalt is fed into the tank from an asphalt melter or unloading system. The internal coils continuously heat the tank, maintaining the asphalt at a constant temperature in a fluid state. During production, the asphalt pump draws asphalt from the tank bottom, passing it through a filter and heater before delivering it to the process. Impurities settle at the tank bottom and are periodically removed through the drain port.

    Difference from Buffer Tank

    • Liquid Asphalt Storage Tank: Large capacity, long-term storage, overall heating, main material storage.
    • Asphalt Buffer Tank: Small capacity, short-term transfer, pressure stabilization and degassing, intermediate link.

    Frequently Asked Questions

    Q1: What is the primary use of a liquid asphalt storage tank? It is primarily used for the long-term, large-capacity storage of high-temperature liquid asphalt, serving as a core component for asphalt mixing plants and waterproofing production lines.
    Q2: Which heating method is most recommended for asphalt storage? Thermal oil circulation heating is the most recommended method as it provides uniform heating, prevents asphalt aging or coking, and offers stable temperature control.
    Q3: How effective is the insulation on these tanks? The tanks use 100–150 mm high-density rock wool or aluminum silicate insulation, resulting in an excellent thermal performance with a temperature drop of less than 1°C per hour.
    Q4: What is the capacity range for horizontal vs. vertical tanks? Horizontal tanks typically range from 5 to 100 tons and are ideal for mobile job sites, while vertical tanks range from 100 to 5,000 tons for large-scale fixed depots.
    Q5: How does the tank handle asphalt fumes and environmental concerns? The tanks are equipped with breather valves and fume collection systems to minimize emissions, ensuring a closed-loop environmental protection process.
    Q6: Can the tank be customized for localized heating? Yes, many designs feature localized rapid heat extraction which only heats the discharge zone, significantly saving energy while maintaining the quality of the remaining asphalt.