Leave Your Message

China Suppliers Factory Liquid Asphalt Buffer Tank with Level Control for Stable Storage and Transport

The liquid asphalt buffer tank, also referred to as the asphalt buffer tank or asphalt intermediate tank, plays a vital role in the asphalt melting, transportation, and production system. As a key product from reputable suppliers in China, this tank is designed to stabilize flow rates, maintain pressure, and provide insulated storage. It effectively eliminates pulsations and bubbles, ensuring a continuous and stable supply to downstream operations. Manufactured in state-of-the-art factories, our asphalt buffer tanks are essential for optimizing efficiency in asphalt processing and delivery.

    Product Description

    The liquid asphalt buffer tank (also known as asphalt buffer tank or asphalt intermediate tank) is a crucial intermediate storage tank in the asphalt melting, transportation and production system. It is mainly used to stabilize the flow rate, maintain pressure, provide insulation storage, eliminate pulsations and bubbles, and ensure continuous and stable supply to the downstream.

    Core Function

    Flow stabilization and buffering

    Absorbing fluctuations and pressure pulses from the upstream (such as the melting unit, pump), and avoiding impacts on the downstream (such as metering, spraying, stirring).

    Thermal insulation and storage

    Short-term storage of high-temperature liquid asphalt (approximately 150–180°C), maintaining fluidity.

    Gas removal and impurity separation

    During the asphalt's stay in the tank, bubbles rise and impurities settle, improving asphalt quality.

    Safe transition

    During the start-up/shutdown or maintenance of upstream and downstream equipment, providing uninterrupted supply, reducing the frequency of system startups.

    Typical Structure (Standard Design)

    Tank body: Vertical cylinder + bottom conical bottom, carbon steel material.

    Heating and insulation: Built-in heat transfer oil coils / steam coils, outer insulation layer (rock wool, polyurethane), preventing asphalt from condensation.

    Top: Feed inlet, flue gas outlet, exhaust, manhole

    Middle lower part: Discharge outlet (pump suction inlet)

    Bottom: Sewage outlet (sludge discharge)

    Attachments: Liquid level gauge, thermometer, differential pressure gauge, overflow port, insulation and heating.

    Working Principle

    1

    High-temperature liquid asphalt enters the tank from the top / side.

    2

    It stays at a low speed in the tank (for several minutes to half an hour), with bubbles escaping and impurities settling.

    3

    The built-in heating tubes maintain insulation and maintain the asphalt temperature and viscosity.

    4

    The bottom discharge outlet is stabilized and transported to the next process by the pump.

    5

    The asphalt flue gas is centrally led to the purification system.

    Application Scenarios

    Carbon / anode production

    Asphalt melting system → buffer tank → liquid asphalt storage tank → impregnation / mixing.

    Road asphalt mixing station

    Asphalt tank → buffer tank (bucket) → metering → spraying and mixing.

    Asphalt loading / transportation

    The buffer tank stabilizes the flow, reducing the pulsation during loading and the splashing of flue gas.

    Differences from "Asphalt Storage Tank"

    Buffer Tank

    Small capacity (1–20 m³), short stay, strong insulation, gas removal and pressure stabilization, intermediate link.

    Storage Tank

    Large capacity (several - several thousand m³), long-term storage, main storage material.

    Frequently Asked Questions

    What is the primary purpose of a liquid asphalt buffer tank?
    It serves as an intermediate unit to stabilize flow rates, maintain pressure, provide thermal insulation storage, eliminate pulsations and air bubbles, and ensure an uninterrupted supply to downstream processes.
    What temperature is maintained inside the buffer tank?
    The buffer tank maintains high-temperature liquid asphalt at approximately 150–180°C using built-in heating coils (steam or heat transfer oil) and outer insulation to preserve fluidity and optimal viscosity.
    How does a buffer tank differ from a standard asphalt storage tank?
    A buffer tank has a smaller capacity (1–20 m³) designed for short retention times, rapid gas removal, and pressure stabilization. In contrast, standard storage tanks feature much larger capacities (up to thousands of m³) designed for long-term raw material holding.
    How does the buffer tank improve overall asphalt quality?
    While the asphalt stays in the tank at low speed (for a few minutes up to half an hour), trapped air bubbles rise and escape, while solid impurities settle toward the bottom discharge, significantly enhancing asphalt purity.
    Where is this buffer tank typically applied in industry?
    It is widely used in carbon and anode production lines, road asphalt mixing stations, and asphalt loading/transportation systems to ensure continuous metering, spraying, and splash-free loading.