China 200m³ Liquid Asphalt Storage Tank - Reliable Suppliers & Factory for High-Temperature Asphalt Solutions
Solutions to Key Challenges in Raw Material Storage
Asphalt is solid at ambient temperature and requires high heat to remain liquid. This storage tank system features internal thermal oil heating coils and rock wool insulation, maintaining a constant operating temperature of 140–170°C. This prevents solidification during prolonged storage, allowing for immediate pumping to the mixing plant and avoiding temperature drops that cause clumping or pipeline blockages.
The system utilizes indirect heating via internal thermal oil coils rather than direct open-flame heating, ensuring uniform and controllable temperatures. The design limits the maximum temperature to 180°C—well below the asphalt flash point (230°C)—preventing scorching, aging, and property degradation. This ensures the base or modified asphalt meets product specifications and road paving quality standards.
Polymers within modified asphalt tend to settle and stratify. The integrated agitation system ensures continuous homogenization, maintaining a uniform composition and preventing issues such as a diluted upper layer and a clumped lower layer. This guarantees stable discharge quality and prevents defects during road construction.
Ensuring Production and Operational Reliability
With an effective capacity of 200 cubic meters, the tank serves as a dedicated reserve for the mixing plant, storing hot asphalt in advance. This mitigates risks associated with delayed tanker deliveries or supply interruptions, ensuring uninterrupted asphalt output and continuous road construction, thereby minimizing losses caused by downtime.
The low-level discharge outlet at the tank bottom maximizes asphalt drainage, minimizing residual sediment and waste. This reduces raw material loss and procurement costs, while an integrated sampling port allows for convenient, real-time testing of asphalt properties.
III. Safety and Compliance: Addressing Tank Farm Safety Risks and Meeting National Standard Acceptance Criteria
Comprehensive safety accessories meeting the GB50341 national standard for vertical storage tanks and satisfying acceptance requirements for transportation engineering, safety supervision, and fire safety authorities:
- Breather valves, overflow ports, and vent ports: Balance internal pressure to prevent overpressure or tank collapse due to negative pressure.
- Radar level gauge + multi-point temperature sensors: Real-time monitoring of material levels and temperatures (top, middle, and bottom) for visual management, preventing dry heating or tank overflow.
- Lightning and static grounding (grounding resistance ≤ 10Ω): Eliminate static electricity and mitigate fire and explosion risks.
- Bund wall and asphalt-sand cushion foundation design: Complies with fire safety regulations for asphalt tank farms, ensuring smooth project completion and acceptance.
The process design limits the maximum temperature to 180°C—below the asphalt flash point—reducing fire risk at the hardware level; standardized maintenance and feed/shutdown logic guide proper operation, preventing accidents such as solidification, burns, or explosions caused by errors like high-temperature filling or feeding into a cold tank.
Engineering Selection and Site-Specific Solutions
Vertical structure saves footprint: For the same 200m³ capacity, a vertical tank occupies significantly less space than a horizontal one, making it ideal for the compact layouts of mixing plants; the atmospheric pressure design results in lower manufacturing, inspection, and O&M costs compared to pressure vessels.
- Base asphalt version: No agitation required, reducing equipment procurement costs.
- Modified asphalt version: Includes agitation to meet storage requirements for modified asphalt, offering flexible selection options.
I. Basic Parameters (200 m³ effective capacity)
| Type | Vertical atmospheric fixed-roof storage tank (standard for asphalt storage) |
|---|---|
| Dimensions (Typical) | Inner diameter Φ6.5 m, shell height ≈ 6.0 m; total volume 210–220 m³, effective volume 200 m³ |
| Design Pressure | Atmospheric (–0.5 to +2 kPa) |
| Design & Operating Temp | Design temperature: 180°C; Operating temperature: Base asphalt 140–160°C; Modified asphalt 150–170°C |
| Materials | Tank shell: Q235-B; Heating coils: 20# seamless steel pipe |
II. Tank Structure
- 1. Tank walls: Wall thickness 8–10 mm; tank bottom 8–10 mm; tank roof 6 mm.
-
2. Heating system:
- Standard: Thermal oil coil heating (coils arranged inside the tank, connected to an external thermal oil heater; prevents localized coking and aging of the asphalt).
- Alternative: Electric heating (for small tanks; generally not recommended for 200 m³ capacity); direct open-flame heating is strictly prohibited.
- 3. Insulation layer: 100–150 mm high-density rock wool or aluminum silicate; outer cladding of 0.5 mm color-coated steel or aluminum sheet to prevent heat loss.
-
4. Ancillary Accessories:
- Manhole (tank top), breather valve, overflow port, vent/drain port.
- Level gauge (radar / differential pressure type), multi-point temperature sensors (bottom, middle, and top of the tank).
- Discharge outlet (low-level outlet at the tank bottom to facilitate complete asphalt drainage), sampling port.
- Agitation system (agitation is recommended for modified asphalt storage tanks to prevent sedimentation and stratification).
- Lightning and static grounding system (grounding resistance ≤ 10Ω).
III. Safety and Process Essentials
- Temperature Control: Asphalt flash point is approximately 230°C; the operating temperature must strictly not exceed 180°C to prevent oxidation, aging, and fire risks.
- Tank Farm: Fire-containment dike; asphalt-sand cushion layer at the tank bottom; tank foundation requires settlement monitoring in compliance with GB50341 standards.
-
Operation:
- Filling: Preheat the tank body before introducing hot asphalt to prevent solidification caused by a cold tank.
- Shutdown: Maintain insulation temperature after stopping the feed; do not allow the temperature to drop directly. Fully drain the asphalt from the tank for long-term shutdowns.
- Maintenance: For tanks containing high-temperature asphalt, maintenance procedures must include cooling, ventilation, and gas testing; entering the tank while it is hot is strictly prohibited.
Comparison with Other Storage Tanks
No heating or insulation; unsuitable for storing hot asphalt.
Require both heating and insulation; key focus is preventing solidification and localized overheating/coking.
Basic Selection Guidelines
- Base asphalt storage: 200m³ vertical tank, thermal oil heating coils; agitation system optional.
- Modified asphalt storage: Agitation system mandatory to prevent polymer sedimentation and stratification.
- Layout considerations: Horizontal tanks may be used if site space is limited; however, a 200m³ horizontal tank has a large footprint, so vertical tanks are generally preferred.
